Global Load Mode
Use Global Load Mode to define how all Multi-Tracer system loads behave.
All Loads Off ---- Sets all modules to open circuit (no load) regardless of individual module channel settings.
All Peak Power --- Forces all channels to peak power track. While peak-power tracking, the Multi-Tracer continuously searches for the operating voltage that produces the maximum output power from the module. Peak power tracking is the most commonly use load mode.
All Fixed Voltage --- Sets all modules to operate at at a fixed voltage. The voltage is set for each module channel individually (see Module Channel Settings).
Channel Defined --- Each module will operate as defined by that module's channel settings (see Module Channel Settings).
Global IV Curve Mode
Use Global IV Curve Mode to define how the Multi-Tracer system takes automatic IV curves.
None ---- The system will not automatically take IV curves regardless of other settings.
All Channels --- Enables all module channels for automatic IV curves regardless of other settings.
Channel Defined --- Automatic IV curves will be taken as defined by the individual module channel settings (see Module Channel Settings).
Note: IV curves may be takening manually at any time (see IV Curve Data). These global settings only affect automatic IV curves.